In-bore 3-T MR-guided transrectal targeted prostate biopsy: Prostate Imaging Reporting and Data System version 2-based diagnostic performance for detection of prostate cancer

Nelly Tan, Wei Chan Lin, Pooria Khoshnoodi, Nazanin H. Asvadi, Jeffrey Yoshida, Daniel J.A. Margolis, David S.K. Lu, Holden Wu, Kyung Hyun Sung, David Y. Lu, Jaioti Huang, Steven S. Raman

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To determine the diagnostic yield of in-bore 3-T magnetic resonance (MR) imaging-guided prostate biopsy and stratify performance according to Prostate Imaging Reporting and Data System (PI-RADS) versions 1 and 2. Materials and Methods: This study was HIPAA compliant and institution review board approved. In-bore 3-T MR-guided prostate biopsy was performed in 134 targets in 106 men who (a) had not previously undergone prostate biopsy, (b) had prior negative biopsy findings with increased prostate-specific antigen (PSA) level, or (c) had a prior history of prostate cancer with increasing PSA level. Clinical, diagnostic 3-T MR imaging was performed with in-bore guided prostate biopsy, and pathology data were collected. The diagnostic yields of MR-guided biopsy per patient and target were analyzed, and differences between biopsy targets with negative and positive findings were determined. Results of logistic regression and areas under the curve were compared between PI-RADS versions 1 and 2. Results: Prostate cancer was detected in 63 of 106 patients (59.4%) and in 72 of 134 targets (53.7%) with 3-T MR imaging. Forty-nine of 72 targets (68.0%) had clinically significant cancer (Gleason score ≥ 7). One complication occurred (urosepsis, 0.9%). Patients who had positive target findings had lower apparent diffusion coefficient values (875 × 10-6 mm2/sec vs 1111 × 10-6 mm2/sec, respectively; P < .01), smaller prostate volume (47.2 cm3 vs 75.4 cm3, respectively; P < .01), higher PSA density (0.16 vs 0.10, respectively; P < .01), and higher proportion of PI-RADS version 2 category 3-5 scores when compared with patients with negative target findings. MR targets with PI-RADS version 2 category 2, 3, 4, and 5 scores had a positive diagnostic yield of three of 23 (13.0%), six of 31 (19.4%), 39 of 50 (78.0%), and 24 of 29 (82.8%) targets, respectively. No differences were detected in areas under the curve for PI-RADS version 2 versus 1. Conclusion: In-bore 3-T MR-guided biopsy is safe and effective for prostate cancer diagnosis when stratified according to PI-RADS versions 1 and 2.

Original languageEnglish
Pages (from-to)130-139
Number of pages10
JournalRadiology
Volume283
Issue number1
DOIs
StatePublished - Apr 2017

ASJC Scopus Subject Areas

  • Radiology Nuclear Medicine and imaging

Cite this