Evaluation of a Chitosan Hemostat in a Porcine Laparoscopic Partial Nephrectomy Model: A Pilot Study

Andrew Crofton, Duane Baldwin, Muhannad Alsyouf, Matthew Dopp, Daniel Faaborg, Kristine Myklak, Javier Arenas, Nazih Khater, Samuel Hudson, Kerby C. Oberg, Wolff M. Kirsch

Research output: Contribution to journalArticlepeer-review

Abstract

Background and Objective: The ideal hemostatic agent for laparoscopic partial nephrectomy (LPN) would provide complete hemostasis and sealing of the collecting system at a low cost. Chitosan (CS) is an established topical hemostatic agent, but standard sterilization techniques affect its functional and biologic properties, thereby preventing parenteral uses. This study sought to characterize the safety and efficacy of an implanted CS hemostat sterilized with either a standard technique, electron beam (e-beam) irradiation, or a novel technique, nonthermal nitrogen plasma, in a porcine LPN model. Methods: Laparoscopic partial nephrectomies were performed on six farm pigs and hemostasis achieved using only a CS hemostatic agent (Clo-Sur P.A.D.) that was e-beam (n = 3) or plasma sterilized (PS) (n = 3). Number of pads needed to achieve hemostasis, estimated blood loss, operative time, mass of kidney resection, and warm ischemia time were measured. Animals were monitored for 14 weeks and at harvest, retrograde ureteropyelography and histologic analysis were performed. Results: Complete hemostasis and collection system sealing were achieved in both groups. There was a trend toward less pads required for hemostasis (p = 0.056) and reduced blood loss (p = 0.096) with PS pads, although this did not achieve statistical significance. No complications were observed for 14 weeks and gross examination showed the implanted CS was encapsulated in a fibrous capsule. Histologic analysis revealed a healed nephrectomy site with residual CS and associated chronic inflammation, reactive fibrosis, and foreign body giant cell formation. Importantly, the adjacent renal tissue was intact and viable with no residual parenchymal inflammation or cytologic damage. Conclusion: CS pads alone provided safe and effective hemostasis in a porcine LPN model. PS may enhance hemostatic efficacy and resorption compared with e-beam.

Original languageEnglish
Pages (from-to)887-894
Number of pages8
JournalJournal of Endourology
Volume33
Issue number11
DOIs
StatePublished - Nov 2019

ASJC Scopus Subject Areas

  • Urology

Keywords

  • LPN
  • chitosan
  • e-beam
  • electron beam
  • hemostasis
  • hemostatic agents
  • laparoscopic partial nephrectomy
  • nonthermal nitrogen plasma
  • plasma sterilization